<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">periodontology</journal-id><journal-title-group><journal-title xml:lang="ru">Пародонтология</journal-title><trans-title-group xml:lang="en"><trans-title>Parodontologiya</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1683-3759</issn><issn pub-type="epub">1726-7269</issn><publisher><publisher-name>Russian Periodontal Association (RPA)</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.33925/1683-3759-2025-1028</article-id><article-id custom-type="elpub" pub-id-type="custom">periodontology-1028</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ИССЛЕДОВАНИЕ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>RESEARCH</subject></subj-group></article-categories><title-group><article-title>Современный подход к программированию эксцентрических окклюзионных движений нижней челюсти и способы оценки состояния стоматогнатического аппарата</article-title><trans-title-group xml:lang="en"><trans-title>A modern approach to modeling eccentric mandibular movements and evaluating the stomatognathic system</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-2651-2699</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Дубова</surname><given-names>Л. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Dubova</surname><given-names>L. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Дубова Любовь Валерьевна, доктор медицинских наук, профессор, заведующая кафедрой ортопедической стоматологии</p><p>Москва</p></bio><bio xml:lang="en"><p>Lubov V. Dubova, DMD, PhD, DSc, Professor, Head of the Department of Prosthodontics</p><p>Moscow</p></bio><email xlink:type="simple">dubova.l@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-7154-2865</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Коркин</surname><given-names>Л. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Korkin</surname><given-names>L. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Коркин Леонид Вячеславович, аспирант кафедры ортопедической стоматологии</p><p>127006, ул. Долгоруковская, д. 4, г. Москва</p></bio><bio xml:lang="en"><p>Leonid V. Korkin, PhD student, Department of the Prosthodontics</p><p>4 Dolgorukovskaya Str., Moscow, 127006</p></bio><email xlink:type="simple">lvk2402@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-0352-8746</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Максимов</surname><given-names>Г. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Maximov</surname><given-names>G. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Максимов Георгий Викторович, кандидат медицинских наук, доцент кафедры ортопедической стоматологии</p><p>Москва</p></bio><bio xml:lang="en"><p>Georgii V. Maksimov, DMD, PhD, Associate Professor, Department of the Prosthodontics</p><p>Moscow </p></bio><email xlink:type="simple">gvmaximov@yandex.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-6308-7623</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Ступников</surname><given-names>А. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Stupnikov</surname><given-names>A. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Ступников Алексей Анатольевич, кандидат медицинских наук, доцент кафедры ортопедической стоматологии</p><p>Москва</p></bio><bio xml:lang="en"><p>Aleksei A. Stupnikov, DMD, PhD, Associate Professor, Department of the Prosthodontics</p><p>Moscow </p></bio><email xlink:type="simple">stupnikow@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Российский университет медицины</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Russian University of Medicine</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2025</year></pub-date><pub-date pub-type="epub"><day>25</day><month>04</month><year>2025</year></pub-date><volume>30</volume><issue>1</issue><fpage>29</fpage><lpage>39</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Дубова Л.В., Коркин Л.В., Максимов Г.В., Ступников А.А., 2025</copyright-statement><copyright-year>2025</copyright-year><copyright-holder xml:lang="ru">Дубова Л.В., Коркин Л.В., Максимов Г.В., Ступников А.А.</copyright-holder><copyright-holder xml:lang="en">Dubova L.V., Korkin L.V., Maximov G.V., Stupnikov A.A.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.parodont.ru/jour/article/view/1028">https://www.parodont.ru/jour/article/view/1028</self-uri><abstract><sec><title>Актуальность</title><p>Актуальность. В настоящее время наблюдается крайне высокая распространенность заболеваний височнонижнечелюстного сустава (ВНЧС). На стоматологическом клиническом приеме при первичном осмотре стоит особое внимание уделять диагностике ВНЧС, так как довольно часто после проведения ортопедического стоматологического лечения, особенно обширного, могут появиться осложнения в виде возникновения или проявления скрытых заболеваний ВНЧС. Сейчас внедрение современных цифровых технологий делает диагностику заболеваний ВНЧС и их лечение по уже утвержденным протоколам (с помощью окклюзионно-стабилизирующего аппарата (ОСА), например) более точными и максимально эффективными.</p></sec><sec><title>Цель исследования</title><p>Цель исследования. Оценить эффективность современного цифрового протокола моделирования окклюзионно-стабилизирующего аппарата и в последующем временных несъемных ортопедических конструкций при лечении пациентов с мышечно-суставной дисфункцией ВНЧС под контролем функциональных методов.</p></sec><sec><title>Материалы и методы</title><p>Материалы и методы. Было проведено клиническое стоматологическое обследование 78 человек, из которых, согласно критериям включения, невключения и исключения были отобраны в основную группу 20 человек (с наличием мышечно-суставной дисфункции ВНЧС) и в контрольную группу 20 человек (без заболеваний ВНЧС). Обследуемым основной группы проводили исследование КТ, а также исследование МРТ ВНЧС. С помощью функционально-диагностического комплекса обследуемым контрольной группы и пациентам основной группы проводили электрогнатографию и электромиографию. По результатам электрогнатографии измеряли угловой показатель эксцентрических движений относительно горизонтальной плоскости и величину данных движений нижней челюсти. По результатам электромиографии оценивали биопотенциалы, а также симметрию и синергию работы жевательных и височных мышц. Полученные данные основной группы до начала лечения и на этапах лечения сравнивали друг с другом и с данными аналогичных исследований контрольной группы. Окклюзионно-стабилизирующий аппарат и временные несъемные ортопедические конструкции изготавливали методом фрезерования с использованием данных КТ, интраорального сканирования и регистрата прикуса после проведения чрескожной электронейростимуляции (ЧЭНС).</p></sec><sec><title>Результаты</title><p>Результаты. По результатам электромиографического исследования основной группы при проведении пробы относительного физиологического покоя получили снижение показателей биопотенциалов группы жевательных мышц в среднем на 60,3% по сравнению с исходными данными до начала лечения. При проведении пробы максимального волевого сжатия челюстей симметрия в работе группы жевательных мышц увеличилась в среднем на 89,5%, а синергия на 61% по сравнению с исходными данными до начала лечения. По данным электрогнатографии в результате проведенного ортопедического лечения у пациентов основной группы произошло увеличение объема эксцентрических окклюзионных движений нижней челюсти в среднем на 71%, а также уменьшение разброса угловых показателей эксцентрических окклюзионных движений в среднем на 77% по сравнению с исходными данными до начала лечения.</p></sec><sec><title>Заключение</title><p>Заключение. Современный цифровой протокол лечения мышечно-суставной дисфункции ВНЧС с использованием индивидуальных параметров при моделировании окклюзионно-стабилизирующего аппарата и несъемных временных конструкций, а также диагностика и контроль результатов при помощи функционально-диагностического комплекса дают стабильный и корректный результат реабилитации пациентов.</p></sec></abstract><trans-abstract xml:lang="en"><sec><title>Relevance</title><p>Relevance. Currently, temporomandibular disorders (TMD) are highly prevalent. During the initial dental consultation and examination, special attention should be given to the diagnosis of TMD, as complications may arise following prosthetic treatment, particularly after extensive procedures, which may manifest as newly emerging or previously undiagnosed TMD disorders. The implementation of modern digital technologies enhances the accuracy and effectiveness of TMD diagnostics and treatment, ensuring compliance with established protocols, including the use of occlusal stabilization appliances (OSA).</p></sec><sec><title>Objective</title><p>Objective. To assess the effectiveness of a modern digital treatment protocol for designing an occlusal stabilization appliance, followed by temporary fixed dental restorations, in the treatment of patients with TMD involving both joint and myofascial dysfunction, with functional diagnostic monitoring.</p></sec><sec><title>Materials and methods</title><p>Materials and methods. A clinical dental examination was performed on 78 individuals. Based on inclusion and exclusion criteria, 20 individuals diagnosed with TMD were assigned to the main group, while 20 individuals without TMD were included in the control group. Participants in the main group underwent cone-beam computed tomography (CBCT) and magnetic resonance imaging (MRI) of the temporomandibular joint (TMJ). Both groups underwent electrognathographic recording (EGG) and surface electromyography (sEMG) using a functional diagnostic system. Electrognathography was used to track and analyze the trajectory and range of eccentric mandibular movements, while angular parameters relative to the horizontal plane were derived from the recorded motion data. Surface electromyography was employed to assess bioelectrical activity, as well as the symmetry and synergy of the masticatory and temporalis muscles. The data collected from the main group were analyzed at different treatment stages and compared with the corresponding data from the control group. Occlusal stabilization appliances and temporary fixed dental restorations were fabricated using milling technology, incorporating CBCT imaging, intraoral scanning, and occlusal registration following transcutaneous electrical nerve stimulation (TENS).</p></sec><sec><title>Results</title><p>Results. In the main group, surface electromyography (sEMG) during the relative physiological rest test revealed a 60.3% average reduction in the bioelectrical activity of the masticatory muscles compared to baseline values before treatment. During the maximum voluntary clenching test, an increase in muscle symmetry of 89.5% on average was observed, while muscle synergy improved by 61% compared to baseline values. According to electrognathographic data, after prosthetic treatment, the main group demonstrated an average 71% increase in the range of eccentric occlusal movements of the mandible, as well as a 77% average reduction in the variability of angular parameters of eccentric occlusal movements compared to baseline values.</p></sec><sec><title>Conclusion</title><p>Conclusion. The use of an advanced digital treatment protocol for temporomandibular disorders (TMD) involving both joint and myofascial dysfunction, based on individualized parameters for modeling occlusal stabilization appliances and temporary fixed dental restorations, as well as functional diagnostics and outcome monitoring, ensures stable and reliable rehabilitation outcomes for patients.</p></sec></trans-abstract><kwd-group xml:lang="ru"><kwd>электрогнатография</kwd><kwd>электромиография</kwd><kwd>височно-нижнечелюстной сустав</kwd><kwd>эксцентрические движения нижней челюсти</kwd><kwd>шинотерапия</kwd><kwd>виртуальный артикулятор</kwd></kwd-group><kwd-group xml:lang="en"><kwd>electrognathography</kwd><kwd>electromyography</kwd><kwd>temporomandibular joint</kwd><kwd>eccentric mandibular movements</kwd><kwd>splint therapy</kwd><kwd>virtual articulator</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Стрекалова ЕЛ, Джашеева ДИ, Халкечева ЛН, Стрекалов АА. Анализ эпидемиологических аспектов расстройств ВНЧС на первичном ортопедическом приеме. Институт стоматологии. 2021;90(1):14-15. Режим доступа: https://www.elibrary.ru/item.asp?id=45632811</mixed-citation><mixed-citation xml:lang="en">Strekalova EL, Dzhasheeva DI, Khalkecheva LN, Strekalov AA. Analysis of epidemiological aspects of TMJ disorders at the first prosthodontic appointment. Institute of Dentistry. 2021;90(1):14-15 (In Russ.). Available from: https://www.elibrary.ru/item.asp?id=45632811</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Арсенина ОИ, Абакаров СИ, Попова НВ, Махортова ПИ, Попова АВ, Жуков ДЮ. Ортодонтическое лечение как этап подготовки к рациональному зубному протезированию. Стоматология. 2023;102(2):54 62. doi: 10.17116/stomat202310202154</mixed-citation><mixed-citation xml:lang="en">Arsenina OI, Abakarov SI, Popova NV, Makhortova PI, Popova AV, Zhukov DYu. Orthodontic treatment as a stage of rational dental prosthetics. Stomatology. 2023;102(2):54 62 (In Russ.). doi: 10.17116/stomat202310202154</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Дубова ЛВ, Золотницкий ИВ, Ступников АА. Использование функционально диагностического комплекса при ортопедическом лечении пациентов с функциональными морфологическими нарушениями ВНЧС. Российская стоматология. 2019;12(3):65-66. Режим доступа: https://www.elibrary.ru/item.asp?id=44018007</mixed-citation><mixed-citation xml:lang="en">Dubova LV, Zolotnitsky IV, Stupnikov AA. Use of a functional diagnostic complex in orthopedic treatment of patients with functional morphological disorders of the TMJ. Russian Dentistry. 2019;12(3):65-66 (In Russ.). Available from: https://www.elibrary.ru/item.asp?id=44018007</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Дубова ЛВ, Ступников ПА, Ступников АА, Буренчев ДВ, Харченко ДА. Обоснование применения комплексного цифрового диагностического алгоритма для обследования пациентов с мышечно-суставной дисфункцией при использовании внутриротового окклюзионного аппарата. Пародонтология. 2021;26(4):260-268. doi: 10.33925/1683-3759-2021-26-4-260-268</mixed-citation><mixed-citation xml:lang="en">Dubova LV, Stupnikov PA, Stupnikov АА, Burenhcev DV, Kharchenko DA. The rationale for the algorithm of comprehensive digital diagnosis of patients with temporomandibular disorders using an intraoral occlusal appliance. Parodontologiya. 2021;26(4):260-268 (In Russ.). doi: 10.33925/1683-3759-2021-26-4-260-268</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Саакян МЮ, Успенская ОА, Рябов СВ, Александров АА. Определение погрешностей в технологии изготовления окклюзионных шин для лечения заболеваний ВНЧС. Проблемы стоматологии. 2020;16(2):129-133. doi: 10.18481/2077-7566-20-16-2-129-133</mixed-citation><mixed-citation xml:lang="en">Saakyan MU, Uspenskaya OA, Ryabov SV, Aleksandrov AA. Determination of errors in the manufacturing technology of occlusive splints for the treatment of TMJ diseases. Actual problems in dentistry. 2020;16(2):129- 133 (In Russ.). doi: 10.18481/2077-7566-20-16-2-129-133</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Nota A, Chegodaeva AD, Ryakhovsky AN, Vykhodtseva MA, Pittari L, Tecco S. One-Stage Virtual Plan of a Complex Orthodontic/Prosthetic Dental Rehabilitation. Int J Environ Res Public Health. 2022 28;19(3):1474. doi: 10.3390/ijerph19031474</mixed-citation><mixed-citation xml:lang="en">Nota A, Chegodaeva AD, Ryakhovsky AN, Vykhodtseva MA, Pittari L, Tecco S. One-Stage Virtual Plan of a Complex Orthodontic/Prosthetic Dental Rehabilitation. Int J Environ Res Public Health. 2022 28;19(3):1474. doi: 10.3390/ijerph19031474</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Ряховский АН, Выходцева МА. Обоснование методики 3D анализа ВНЧС по данным компьютерной томографии. Стоматология. 2022;101(1):23-32. doi: 10.17116/stomat202210101123</mixed-citation><mixed-citation xml:lang="en">Ryakhovsky AN, Vykhodtseva MA. Validation of the technique of TMJ 3D analysis based on computer tomography. Stomatologiia. 2022;101(1):23-32 (In Russ.). doi: 10.17116/stomat202210101123</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Ряховский АН, Лосев ФФ, Алтынбеков КД, Выходцева МА. Цифровой 3d анализ анатомических и функциональных параметров ВНЧС и их корреляция. Стоматология. 2022;101(3):49-60. doi: 10.17116/stomat2022101031498.</mixed-citation><mixed-citation xml:lang="en">Ryakhovsky AN, Losev FF, Altynbekov KD, Vykhodtseva MA. 3D analysis of anatomical and functional parameters of TMJ and their correlation. Stomatologiia. 2022;101(3):49-60 (In Russ.). doi: 10.17116/stomat202210103149</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Стафеев АА, Ряховский АН, Петров ПО, Чикунов СО, Хижук АВ. Сравнительный анализ воспроизводимости центрального соотношения челюстей с использованием цифровых технологий. Стоматология. 2019;98(6):83-89. doi: 10.17116/stomat20199806183</mixed-citation><mixed-citation xml:lang="en">Stafeev AA, Ryakhovsky AN, Petrov PO, Chikunov SO, Khizhuk AV. A comparative analysis of reproducibility of the jaws centric relation determined with the use of digital technologies. Stomatologiia. 2019;98(6):83-89 (In Russ.). doi: 10.17116/stomat20199806183</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Kihara H, Hatakeyama W, Komine F, Takafuji K, Takahashi T, Yokota J, et al. Accuracy and practicality of intraoral scanner in dentistry: A literature review. Journal of prosthodontic research (Japan). 2020;64(2):109–113. doi: 10.1016/j.jpor.2019.07.010</mixed-citation><mixed-citation xml:lang="en">Kihara H, Hatakeyama W, Komine F, Takafuji K, Takahashi T, Yokota J, et al. Accuracy and practicality of intraoral scanner in dentistry: A literature review. Journal of prosthodontic research (Japan). 2020;64(2):109–113. doi: 10.1016/j.jpor.2019.07.010</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Kernen F, Schlager S, Seidel Alvarez V, Mehrhof J, Vach K, Kohal R, et al. Accuracy of intraoral scans: An in vivo study of different scanning devices. The Journal of prosthetic dentistry (USA). 2021;21:1–7. doi: 10.1016/j.prosdent.2021.03.007</mixed-citation><mixed-citation xml:lang="en">Kernen F, Schlager S, Seidel Alvarez V, Mehrhof J, Vach K, Kohal R, et al. Accuracy of intraoral scans: An in vivo study of different scanning devices. The Journal of prosthetic dentistry (USA). 2021;21:1–7. doi: 10.1016/j.prosdent.2021.03.007</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Marcel R, Reinhard H, Andreas K. Accuracy of CAD/CAM-fabricated bite splints: milling vs 3D printing. Clinical oral investigations (Germany). 2020;24(12):4607–4615. doi: 10.1007/s00784-020-03329-x</mixed-citation><mixed-citation xml:lang="en">Marcel R, Reinhard H, Andreas K. Accuracy of CAD/ CAM-fabricated bite splints: milling vs 3D printing. Clinical oral investigations (Germany). 2020;24(12):4607–4615. doi: 10.1007/s00784-020-03329-x</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Park JH, Lee GH, Moon DN, Kim JC, Park M, Lee KM. A digital approach to the evaluation of mandibular position by using a virtual articulator. The Journal of prosthetic dentistry (USA). 2021;125(6):849–853. doi: 10.1016/j.prosdent.2020.04.002</mixed-citation><mixed-citation xml:lang="en">Park JH, Lee GH, Moon DN, Kim JC, Park M, Lee KM. A digital approach to the evaluation of mandibular position by using a virtual articulator. The Journal of prosthetic dentistry (USA). 2021;125(6):849–853. doi: 10.1016/j.prosdent.2020.04.002</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
